22
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
Rebuilding a defunct drive
A physical drive is defunct when there is a loss of communication between the
controller and the physical drive. This can be caused by any of the following:
•
An improperly connected cable, physical drive, or controller
•
A loss of power to a drive
•
A defective cable, backplane, physical drive or controller
In each case, the communication problem needs to be resolved, and then a rebuild
operation is required to reconstruct the data for the device in its disk array. The
ServeRAID controllers can reconstruct RAID level-1 and RAID level-5 logical drives,
but they cannot reconstruct data stored in RAID level-0 logical drives.
07
6C
Explanation:
Online/rebuild and ready/standby drives are not responding, a drive
was found at the incorrect SCSI ID, and unidentified drives were found.
Action:
Press F4, F5, F6, or F10.
07
78
Explanation:
Online/rebuild, ready/standby, and hot-spare/standby hot-spare
drives are not responding, and unidentified drives were found.
Action:
Press F4, F5, or F10.
07
7C
Explanation:
Online/rebuild, ready/standby, and hot-spare/standby hot-spare
drives are not responding, a drive was found at the incorrect SCSI ID, and
unidentified drives were found.
Action:
Press F4, F5, F6, or F10.
09
00
Explanation:
No error occurred.
Action:
No action is required.
09
10
Explanation:
Hot-spare/standby hot-spare drives are not responding.
Action:
Press F4, F5, or F10.
09
20
Explanation:
Ready/standby drives are not responding.
Action:
Press F4, F5, or F10.
09
30
Explanation:
Hot-spare/standby hot-spare and ready/standby drives are not
responding.
Action:
Press F4, F5, or F10.
0F
00
Explanation:
No error occurred.
Action:
No action is required.
0F
10
Explanation:
Hot-spare/standby hot-spare drives are not responding.
Action:
Press F4, F5, or F10.
0F
20
Explanation:
Ready/standby drives are not responding.
Action:
Press F4, F5, or F10.
0F
30
Explanation:
Hot-spare/standby hot-spare and ready/standby drives are not
responding.
Action:
Press F4, F5, or F10.
BCS
ECS
Explanation and possible recovery action
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......