To remove a hot-swap power supply:
1. If your server has only two functioning power supplies
and requires both (see “Hot-Swap Power Supply
Installation” on page 115), turn off the server and
peripheral devices (see “Preparing to Install Options”
on page 160); otherwise, go to the next step.
Attention
Before removing a functional power supply, set
the Power switch on the power supply to the Off
position.
2. Set the Power switch on the power supply that you
are removing to the Off position.
3. Remove the power supply:
a. Remove any shipping screws from the power
supply.
Note
You do not need to replace the shipping
screws.
b. Pull the handle on the power supply; then, slide
the power supply out of the chassis.
Note
During normal operation, be sure that each
power-supply bay has either a power supply
or filler panel installed for proper cooling.
4. If you are not installing a replacement power supply,
install a power-supply filler panel
.2/
; then go to step
5.
If you are replacing the power supply:
a. Place the handle
.4/
on the power supply in the
open position, and slide the power supply into
the chassis.
b. Close the handle on the power supply to seat
the power supply in the bay.
c. Make sure the Power switch on the power
supply is in the On position.
d. Verify that the AC Power light and DC Power
light are lit, indicating that the power supply is
operating correctly.
5. If you have other options to install or remove, do so
now; otherwise, go to “Completing the Installation” on
page 97.
Netfinity 7000-M10 - Type 8680
119
Summary of Contents for 86803RU - Netfinity 7000 M10
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 110: ...1 5 6 9 102 Netfinity Server HMM...
Page 232: ...224 Netfinity Server HMM...
Page 249: ...Related Service Information 241...
Page 250: ...242 Netfinity Server HMM...
Page 251: ...Related Service Information 243...
Page 252: ...244 Netfinity Server HMM...
Page 253: ...Related Service Information 245...
Page 266: ...258 Netfinity Server HMM...
Page 267: ...Related Service Information 259...
Page 268: ...260 Netfinity Server HMM...
Page 278: ...IBM Part Number 09N1052 Printed in U S A S 1K 4643 2...