Enabled Alerts Dialout Group:
Use the selections
available in the Enabled Alerts Dialout group to specify
which system management subsystem events will result in
all currently configured Dialout Entries being contacted by
the system management subsystem. Any selected items
will, if detected by the system management subsystem,
result in an alert describing the event being forwarded,
using the method selected in the Type field, to the
recipient specified by the Dialout Entry.
If the alert is being forwarded to a pager, Advanced
System Management will include information about the
event that triggered the alert. If the alert is forwarded to a
numeric (or standard), pager, the page will include a code
number that corresponds to the triggering event. If the
alert is forwarded to an alphanumeric pager, the page will
include both a code number and a text string that describe
the triggering event. For more information on the numeric
codes and text strings that are transmitted to pagers, refer
to the following tables.
The Enabled Alerts Dialout group is divided into the
Critical, Non-critical, and System groups. The Critical
Enabled Alerts Dialout group contains the following items.
Item
Description (if checked)
Numeric
Code
Text
String
Temperature
The system management
subsystem will dial out and
then automatically initiate a
system shutdown if any
monitored temperatures
exceed their threshold
values.
00
Temperature
Voltage
The system management
subsystem will dial out if
the voltages of any
monitored power sources
fall outside their specified
operational ranges.
01
Voltage
Tamper
The system management
subsystem will add an
entry in the Event Log if six
consecutive remote login
attempts fail.
02
Tamper
Multiple fan
failure
The system management
subsystem will dial out if
two (or more) of the
system's cooling fans fail
and will automatically
initiate a system shutdown.
03
Multiple
Fan
Failure
Power failure
The system management
subsystem will dial out if
the system's power supply
fails.
04
Power
Failure
Hard disk drive
The system management
subsystem will dial out if
one or more of the hard
disk drives in the system
fail.
05
Hard
Drive
62
Netfinity Server HMM
Summary of Contents for 86803RU - Netfinity 7000 M10
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 110: ...1 5 6 9 102 Netfinity Server HMM...
Page 232: ...224 Netfinity Server HMM...
Page 249: ...Related Service Information 241...
Page 250: ...242 Netfinity Server HMM...
Page 251: ...Related Service Information 243...
Page 252: ...244 Netfinity Server HMM...
Page 253: ...Related Service Information 245...
Page 266: ...258 Netfinity Server HMM...
Page 267: ...Related Service Information 259...
Page 268: ...260 Netfinity Server HMM...
Page 278: ...IBM Part Number 09N1052 Printed in U S A S 1K 4643 2...