96
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
✏
NOTE
See “System” on page 130 to determine which components should be replaced by a field
service technician.
Beep/symptom
FRU/action
1-1-2
(Microprocessor register test
failed)
1. Optional microprocessor (if installed)
2.
Microprocessor
3.
System board assembly
1-1-3
(CMOS write/read test failed)
1. Battery
2.
System board assembly
1-1-4
(BIOS ROM checksum failed)
1. Flash BIOS.
2.
DIMM.
3.
System board assembly.
1-2-1
(Programmable Interval Timer
failed)
•
System board assembly
1-2-2
(DMA initialization failed)
•
System board assembly
1-2-3
(DMA page register write/read
failed)
•
System board assembly
1-2-4
(RAM refresh verification failed)
1. DIMM
2.
System board assembly
1-3-1
(first 64K RAM test failed)
1. DIMM
2.
System board assembly
1-3-2
(first 64K RAM parity test failed)
1. DIMM
2.
System board assembly
2-1-1
(Secondary DMA register failed)
•
System board assembly
2-1-2
(Primary DMA register failed)
•
System board assembly
2-1-3
(Primary interrupt mask register
failed)
•
System board assembly
2-1-4
(Secondary interrupt mask
register failed)
•
System board assembly
2-2-1
(Interrupt vector loading failed)
•
System board assembly
2-2-2
(Keyboard controller failed)
1. Keyboard
2.
System board assembly
3.
Management module
Summary of Contents for 8832L1X
Page 62: ...46 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 148: ...132 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 154: ...138 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...