102
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
POST error codes
In the following error codes, X can be any number or letter.
202-XXX-001
(Failed system cache test)
1. Microprocessor 1
2.
System board assembly
202-XXX-002
(Failed system cache test)
1. Microprocessor 2
2.
System board assembly
217-198-XXX
(Could not establish drive parameters)
•
SCSI storage expansion unit
217-XXX-000
(Failed hard disk drive test)
✏
NOTE
If RAID is configured, the
hard disk drive number
refers to the RAID logical
array.
•
Hard disk drive 1
217-XXX-001
(Failed hard disk test)
✏
NOTE
If RAID is configured, the
hard disk number refers to
the RAID logical array.
•
Hard disk drive 2
405-XXX-000
(Failed Ethernet test on controller on the
system board)
1. Verify that Ethernet is not disabled in BIOS.
2.
System board assembly.
✏
NOTE
See “System” on page 130 to determine which components should be replaced by a field
service technician.
Error code/symptom
FRU/action
Summary of Contents for 8832L1X
Page 62: ...46 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 148: ...132 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 154: ...138 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...