109
DIMM x error
A memory error occurred.
1. Reseat the DIMM indicated by the
lit DIMM failure LED.
2.
Replace the DIMM.
✏
NOTE
Multiple DIMM LEDs do not
necessarily indicate multiple
DIMM failures. If more than
one DIMM LED is on,
reseat/replace one DIMM at a
time until error goes away.
Refer to the SBCE
management module system
error log for further isolation.
Processor x
error
The microprocessor has failed.
1. Verify that the microprocessor
indicated by the lit LED is installed
correctly. (See “Installing an
additional processor” on page 25
for installation instructions).
2.
Replace the microprocessor.
Temperature
error
The system temperature has exceeded a
threshold level.
1. Check to see if a blower on the
SBCE unit has failed. If it has,
replace the fan.
2.
Make sure the room temperature is not
too high. (See “Features and
specifications” on page 4 for
temperature information.)
System board
error
The system board has failed
1. Replace the blade server cover,
reinsert the blade server in the
SBCE unit, and then restart the
server.
2.
Replace the system board assembly.
NMI error
The system board has failed.
1. Replace the blade server cover,
reinsert the blade server in the
SBCE unit, and then restart the
blade server.
2.
Check the system error log for
information about the error.
If the problem remains, replace the
system board assembly.
Processor
mismatch
The processors do not match.
•
Verify that microprocessors 1 and 2
have the same cache size and type and
the same clock speed. Internal and
external clock frequencies must be
identical; also see “Error symptoms” on
page 110.
Lit blade-error
LED Cause
Action