Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
The blade server does not
turn on.
1. Verify that:
a.
The power LED on the front of the SBCE unit is on.
b.
The LEDs on all the SBCE power modules are on.
c.
If the blade server or attached storage expansion unit is in blade bay
7-14, power modules are in power bays 1, 2, 3 and 4.
d.
The power-on LED on the blade server control panel is blinking
slowly.
•
If the power LED is blinking rapidly and continues to do so, the
blade server is not communicating with the management
module; reseat the blade server, then go to step
<$elemparanumonly<$elemparanumonly<$elemparanumonly
•
If the power LED is off, the blade bay is not receiving power, the
blade server is defective, or the LED information panel is loose
or defective.
e.
Local power control for the blade server is enabled (use the SBCE
management module Web interface to verify), or the blade server
was instructed through the management module (Web interface) to
turn on.
2.
If you just installed an option in the blade server, remove it, and restart the
blade server. If the blade server= now turns on, you might have installed
more options than the power to that blade bay supports.
3.
Try another blade server in the blade bay; if it works, replace the faulty
blade server.
4.
See “Undetermined problems” on page 126.
The blade server does not
turn on and the following
conditions are present:
1. The amber system
error LED on the
SBCE unit’s system
LED panel is lit;
2.
The amber blade error
LED on the blade
server’s LED panel is lit;
and
3.
The system error log
contains the message
"CPUs mismatched".
•
The microprocessor with the lowest feature set must be used as the
Bootstrap Processor (microprocessor 1 in location U66; see “System
board component locations” on page 49). Move the microprocessor in
location U66 to location U70, and move the microprocessor in location
U70 to location U66.
✏
NOTE
See “System” on page 130 to determine which components should be replaced by a field
service technician.
Power problems
Symptom
FRU/action