125
System shutdown
Refer to the following tables when experiencing system shutdown related to voltage or temperature
problems.
System errors
System under recommended 5V fault.
1. Reseat blade server.
2.
Replace blade server.
✏
NOTE
See “System” on page 130 to determine which components should be replaced by a field
service technician.
Message
Action
✏
NOTE
See “System” on page 130 to determine which components should be replaced by a field
service technician.
Message
Action
Internal Error CPU x fault
1. Reseat:
a.
I/O Expansion Option
b.
Blade Storage Expansion option.
c.
Hard disk drive.
2.
Replace:
a.
Failing PCI adapter
b.
Microprocessor x.
c.
I/O Expansion Option.
d.
Blade Storage Expansion option.
e.
Hard disk drive.
f.
System board assembly.