Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
See “Diagnosing problems using Light Path Diagnostics” on page 70 for information on what
action to take if there is a component error.
Table 3. SW4 Light Path Diagnostics LED locations
LED error
Action
NMI
Check the error log for additional information. Reboot the
blade server. If the error still exists, replace the system board.
MIS
Check the processors to make sure they are at the same
speed.
SBRD
Reboot the blade server. If the error still exists, replace the
system board.
TEMP
Check the SBCE unit blowers and air inlets. Check the room
temperature.
Light Path Diagnostics LED
Check the Light Path Diagnostics LED for errors
Light Path Diagnostics button (SW4)
Press SW4 to locate faults on the system board. If the
processor or memory LED is lit, reseat the component. If the
LED remains lit, replace the defective component.