37
d. Push the tray handle to the closed (locked) position.
e.
Check the hard disk drive LEDs to verify that the hard disk drive is operating properly.
•
If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty
and must be replaced.
•
If the green hard disk drive activity LED is flashing, the drive is being accessed.
Opening the SCSI storage expansion unit cover
The following illustration shows how to open the expansion unit cover.
Complete the following steps to open the expansion unit cover:
1. Read the safety information beginning on page “Installation guidelines” on page 17.
2. Carefully lay the expansion unit down on a flat, non-conductive surface, with the cover side up.
3. Press the unit-cover release on each side of the expansion unit and lift the cover open, as shown
in the illustration.
4. Lay the cover flat, or lift it from the expansion unit and store for future use.
Statement 21:
xx
CAUTION:
Hazardous energy is present when the blade server is connected to the power source. Always
replace the blade cover before installing the blade server.
Cover release
(both sides)
Summary of Contents for 8832L1X
Page 62: ...46 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 148: ...132 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...
Page 154: ...138 Intel Server Compute Blade SBX82 Hardware Maintenance Manual and Troubleshooting Guide...