75
3. The Linux update package contains the
lflash
utility and the associated BIOS files.
4. Open a command shell and run the “Intel
®
Server Compute Blade Windows BIOS Update” with
the following command line:
<update>.sh -x <path>
where
<update>.sh
is the downloaded update and
<path>
is the path to which the Linux
update files will be extracted.
Steps to extract DOS update files to diskette in Unattended Mode
(Command Line)
1. Boot the system into the Linux operating system.
2. Download the appropriate Linux Update package for the Intel
®
Server Compute Blade SBX82.
(Contact your Intel customer representative for more information.)
3. The Linux update package contains the
lflash
utility and the associated BIOS files.
4. Open a command shell and run the “Intel
®
Server Compute Blade Windows BIOS Update” with
the following command line:
<update>.sh -xd <drive>
where
<update>.sh
is the downloaded update and
<drive>
is the drive to which the DOS
update files will be extracted.
System Event Log messages
The baseboard management controller (BMC) system event log (SEL) contains up to 512 of the
most recent service processor errors in IPMI format. These messages are a combination of plain text
and error code numbers. The SEL can be viewed using the SEL Viewer utility, the Diagnostics
utility, and the Configuration Setup utility as described below:
•
The SEL Viewer utility provides the capability to examine all SEL records in either text or
hexadecimal format, to save the SEL to a file, to examine previously stored SEL records from a
file, to sort all SEL records by various fields in text format, and to clear all SEL entries.
•
The Diagnostics utility provides the capability to view and save all SEL records in text format.
To view the SEL from the Diagnostics menu, select Hardware > BMC Log.
•
The Configuration Setup utility only allows you the ability to view each individual SEL record
separately. No additional functions/capabilities are available. To view individual SEL records
from the Configuration/Setup Utility menu, select Advanced>Baseboard Management
Controller (BMC) Settings>BMC System Event Log.
SEL Viewer utility
The SEL Viewer utility is used to view the SEL records for the Intel® Server Compute Blade
SBX82. The utility can be run in an interactive GUI mode through a series of pull-down menus or by
using the basic command-line arguments.
This utility provides support for performing the following functions:
✏
NOTE
Not all functions are available via the command-line arguments.