Note:
See
“System”
on
page
108
to
determine
which
components
a
field
service
technician
should
replace.
Error
code/symptom
FRU/action
166-407-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
Operator
information
panel
cable.
4.
Operator
information
panel.
5.
System
board.
166-NNN-001
System
Management:
Failed
(BMC
indicates
failure
in
self
test
where
NNN=300
to
320.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
System
board.
166-NNN-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test
where
NNN=400
to
420
(excluding
412,
414,
and
415).)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
System
board.
166-412-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test
where
NNN=400
to
420)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
Power
backplane
4.
System
board.
166-414-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test
where
NNN=400
to
420)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
SCSI
cable
4.
SCSI
backplane
5.
System
board.
166-415-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test
where
NNN=400
to
420)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
Operator
panel
cable
4.
Operator
panel
5.
System
board.
180-XXX-000
(Diagnostics
LED
failure)
Run
diagnostics
panel
LED
test
for
the
failing
LED.
180-XXX-001
(Failed
front
LED
panel
test)
1.
Operator
information
panel
2.
System
board
180-XXX-002
(Failed
diagnostics
LED
panel
test)
1.
Diagnostics
panel
2.
System
board
180-361-003
(Failed
fan
LED
test)
1.
Fan
(s)
2.
System
board
180-XXX-003
(Failed
system
board
LED
test)
System
board
180-XXX-005
(Failed
SCSI
backplane
LED
test)
1.
SCSI
backplane
2.
SCSI
backplane
cable
3.
System
board
Chapter
6.
Symptom-to-FRU
index
89
Summary of Contents for 884015U
Page 1: ...xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 8: ...vi xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 18: ...8 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 82: ...72 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 139: ...Appendix B Safety information 129...
Page 140: ...130 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 141: ...Appendix B Safety information 131...
Page 142: ...132 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 143: ...Appendix B Safety information 133...
Page 155: ...Appendix B Safety information 145...
Page 156: ...146 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 157: ...Appendix B Safety information 147...
Page 158: ...148 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 164: ...154 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ......
Page 176: ...Part Number 25K8115 Printed in USA 1P P N 25K8115...