v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Types
1885
and
8853,”
on
page
15
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
message
Action
Microprocessor
xx
halted
1.
Remove
the
blade
server
from
the
BladeCenter;
then,
reinstall
it.
2.
Reseat
the
microprocessor
xx
.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Replace
the
microprocessor
xx
b.
(Trained
service
technician
only)
System
board
assembly
Microprocessor
xx
temperature
warning
1.
Make
sure
that
the
blade
server
is
sufficiently
cooled.
2.
Make
sure
that
the
that
all
microprocessor
fillers
are
installed
correctly.
3.
Make
sure
that
the
that
the
front
bezel
on
the
blade
server
is
not
blocked.
4.
(Trained
service
technician
only)
Replace
microprocessor
xx
.
Firmware
(BIOS)
backup
ROM
corruption,
System
board
failure
1.
Update
the
blade
server
firmware.
2.
Replace
the
Blade
Storage
Expansion
Unit
3.
Planar
voltage
fault
(power
12V
fault)
1.
Remove
the
blade
server
from
the
BladeCenter;
then,
reinstall
it.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Planar
voltage
fault
(planar
fault)
1.
Remove
the
blade
server
from
the
BladeCenter;
then,
reinstall
it.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Power
controller
timeout
1.
Remove
the
blade
server
from
the
BladeCenter;
then,
reinstall
it.
2.
(Trained
service
technician
only)
Replace
system
board
assembly.
Incompatible
power
controller
firmware
(Trained
service
technician
only)
Replace
system
board
assembly.
Blade
incompatible
with
chassis
1.
Make
sure
that
the
management-module
firmware
is
at
the
latest
level.
2.
If
the
firmware
is
at
latest
level,
the
blade
device
is
not
supported
by
BladeCenter
unit
in
which
it
is
installed.
Firmware
(BIOS)
ROM
corruption
detected
Update
the
BIOS
code.
Chapter
5.
Diagnostics
61
Summary of Contents for 8853L6U
Page 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 30: ...14 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 145: ......