b.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
2
on
node
1;
then,
route
the
cable
through
the
node
1
cable-management
arm.
Use
a
2.9-m
(9.5-foot)
SMP
Expansion
cable
for
this
connection.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
1;
then,
route
the
cable
through
the
node
1
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
4.
Connect
the
SMP
Expansion
cables
to
node
2:
a.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
1
on
node
2;
then,
route
the
cable
through
the
node
2
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
b.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
2
on
node
2;
then,
route
the
cable
through
the
node
2
cable-management
arm.
Use
a
2.9-m
(9.5-foot)
SMP
Expansion
cable
for
this
connection.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
2.
Next,
route
the
cable
through
the
node
2
cable-management
arm.
5.
Connect
the
SMP
Expansion
cables
to
node
3:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
2;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
3.
Next,
route
the
cable
through
the
node
3
cable-management
arm.
b.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
2
on
node
3;
then,
route
the
cable
through
the
node
3
cable-management
arm.
Use
a
2.9-m
(9.5-foot)
SMP
Expansion
cable
for
this
connection.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
3;
then,
route
the
cable
through
the
node
3
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
6.
Connect
the
SMP
Expansion
cables
to
node
4:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
4.
Next,
route
the
cable
through
the
node
4
cable-management
arm.
b.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
2
on
node
4;
then,
route
the
cable
through
the
node
4
cable-management
arm.
Use
a
2.9-m
(9.5-foot)
SMP
Expansion
cable
for
this
connection.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
3;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
4.
Next,
route
the
cable
through
the
node
4
cable-management
arm.
7.
Connect
the
SMP
Expansion
cables
to
node
5:
a.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
1
on
node
5;
then,
route
the
cable
through
the
node
5
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
5.
Next,
route
the
cable
through
the
node
5
cable-management
arm.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
5;
then,
route
the
cable
through
the
node
5
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
8.
Connect
the
SMP
Expansion
cables
to
node
6:
a.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
1
on
node
6;
then,
route
the
cable
through
the
node
6
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
28
IBM
System
x3950
Type
8872
and
System
x3950
E
Type
8874:
Installation
Guide
Summary of Contents for 88728AU - System x3950 - 8872 Datacenter High Availability
Page 3: ...IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 42: ...30 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 68: ...56 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 104: ...92 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Page 105: ......
Page 106: ...Part Number 31R1855 Printed in USA 1P P N 31R1855...