No
Continue at step 6.
Yes
If the original problem still exists, replace the FRU or perform the isolation procedure that is
next in the FRU list. If you have reached the end of the FRU list, contact your next level of
support.
If a new problem occurs, go to Beginning problem analysis.
6.
If the Resource Repair Action menu is already displayed, go to step 9; otherwise, perform the
following steps:
a.
Log into the operating system either with root authority (if needed, ask the customer to enter the
password) or use the CE login.
b.
Enter
diag -a
command and check for missing resources. Follow any instructions that are
displayed. If an SRN displays, suspect a loose card or connection. If no instructions are
displayed, no resources were detected as missing. Continue with the next step.
7.
Perform the following steps:
a.
Enter
diag
at the command prompt.
b.
Press Enter.
c.
Select the Diagnostics Routines option.
d.
When the Diagnostic Mode Selection menu is displayed, select System verification.
e.
When the Diagnostic Selection menu is displayed, select the All Resources option or test the
FRUs you exchanged and any devices that are attached to the FRUs you exchanged by selecting
the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
No
Continue with the next step.
Yes
Go to step 9.
8.
Did the TESTING COMPLETE, no trouble was found menu (801010) display?
No
If the original problem still exists, replace the FRU or perform the isolation procedure that is
next in the FRU list. If you have reached the end of the FRU list, contact your next level of
support.
If a new problem occurs go to Beginning problem analysis.
Yes
Use the Log Repair Action option, if not previously logged, in the TASK SELECTION menu
to update the AIX error log. If the repair action was reseating a cable or adapter, select the
resource associated with that repair action.
If the resource associated with your action is not displayed on the resource list, select
sysplanar0
.
Note:
If the check log indicator is on, this action will set it back to the normal state.
Go to step 11 on page 64.
9.
When a test is run on a resource in system verification mode, that resource has an entry in the AIX
error log. If the test on that resource was successful, the Resource Repair Action menu is displayed.
After replacing a FRU, you must select the resource for that FRU from the Resource Repair Action
menu. This updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Note:
If the check log indicator is on, this action will set it back to the normal state.
Perform the following steps:
a.
Select the resource that has been replaced from the Resource Repair Action menu. If the repair
action was reseating a cable or adapter, select the resource associated with that repair action. If
the resource associated with your action is not displayed on the resource list, select sysplanar0.
b.
Press Commit after you make your selections.
Common procedures for removing or replacing the system processor module
63
Summary of Contents for 9008-22L
Page 1: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Page 2: ......
Page 3: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Page 16: ...xiv Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Page 108: ...92 Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Page 109: ......
Page 110: ...IBM...