a. Push the release latches (A) in the direction shown in the following figure.
b. Slide the cover (B) off the system unit as shown in the following figure. When the front of the
service access cover has cleared the upper frame ledge, lift the cover up and off the system unit.
Figure 54. Removing the service access cover
Permanently removing a memory riser from the 9040-MR9 system
To permanently remove a memory riser from the system, complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Remove the memory riser.
a) Open the release latches (A) on the memory riser as shown in the following figure.
Open the latches to the fully upright 90 degree position.
b) Pull out the memory riser from the slot by holding onto the latches.
Memory riser for the 9040-MR9 75