background image

Install the slide rail assemblies

4

4.1

4.2

Locate the rack-mounting template, the rack-mounting hardware kit, and the slide rail
assemblies that were included with your server.

Use the rack-mounting template to determine where in the rack to place the server. Remove
any filler panels necessary to allow adequate access to the location where you will install
your server.

If you do not have enough space around your rack to open the front and back doors completely, remove
the doors before starting this task to allow adequate access.

4.3

Follow the rack-mounting template to mark the location on
the rack where you will place the server. Use the self-
adhesive placement dots found on the rack-mounting
template.

4.4

Pull the back latch-assembly
release tabs

to the retracted

position and lock the latch
assembly . Make sure the

alignment pins

that are

located on the back of the slide
rail are fully retracted.

C

B

D

From the back of the rack,
insert the front alignment pin

into the hole in the front of the
rack, as identified by the self-
adhesive placement dot.

D

1.

2.

Install the slide rail assemblies .

A

Note:

Install units into the lower part of the rack first. Place

larger and heavier units in the lower part of the rack.

C

B

Front

Back

A

D

Summary of Contents for 9407-515

Page 1: ...Quick start guide for i5 520 525 and 515 9405 520 9406 520 9406 525 and 9407 515 IBM Systems...

Page 2: ...al injury Before doing a step that contains a caution icon read and understand the caution statement that accompanies it This Quick start guide contains an abbreviated set of setup instructions design...

Page 3: ...owing resources If you are not installing your server into a rack skip to task 7 Cable the server and Operations Console LAN If you are installing your server into a rack you will need the following p...

Page 4: ...the installation Use the wrench that was provided with your rack to level the rack by raising or lowering the front and back leveling feet Install the stabilizer bracket on the front of the rack If ne...

Page 5: ...equate access 4 3 Follow the rack mounting template to mark the location on the rack where you will place the server Use the self adhesive placement dots found on the rack mounting template 4 4 Pull t...

Page 6: ...above the hole where you will place the latch bracket screw Finger tighten the screw K L 4 8 3 Align the retracted back pins with the holes identified by the self adhesive placement dots Place the ra...

Page 7: ...the server back into the rack Pull the server back out and push it in again to make sure that the rails are aligned correctly and that it glides smoothly F Tip 5 5 Remove the four blue knobs B 5 8 Us...

Page 8: ...the cable management arm and the two pins E A 6 2 Use the second pin to affix the other end of the cable management arm to the flange that is attached to the sliding portion of the left slide rail as...

Page 9: ...tached follow the setup instructions in the IBM Systems Hardware Information Center For details about how to access the information center see task 11 Finish your system setup If you are using a PC th...

Page 10: ...3 7 8 Connect your server to a power source The control panel should be lit and display The server is not yet powered on If does not display see the instructions in the IBM Systems Hardware Informatio...

Page 11: ...r the port labeled HMC2 on the back of the server No other console device can be attached to the remaining HMC port When you are prompted on the Thin Console display type a new HMC access password Thi...

Page 12: ...are not using an HMC to manage your server skip this task and go to task 10 Cable the server and twinaxial console Finish your system setup If you are using any optional adapters for the HMC connect...

Page 13: ...10 9 11 Connect the server to a power source and wait for the control panel on the front of the server to display This might take several minutes 01 Press the white Power On button on the control pan...

Page 14: ...connect the power cords to a power source until instructed to do so 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 Important The workstation address of your console must be set to 0 To set the address see t...

Page 15: ...install software apply fixes and establish connections with your service provider now IBM Systems Hardware Information Center If you cannot access the online version of the information center it is al...

Page 16: ...bm com systems infocenter hardware References in this publication to IBM products or services do not imply that IBM intends to make them available in every country or region Microsoft Windows Windows...

Reviews: