006 (continued)
ARE THE VOLTAGES CORRECT AND DOES THE FAN RUN?
Yes No
007
Replace the power supply.
008
– The power supply is working normally. (If you suspect the on/off switch
cable assembly, see Step 009.) If the fan continues to run when all
connectors are plugged back in, go to “Undetermined Problem” on
page 2-69. If the fan stops running when a drive connector is plugged
back in, go to “Factory-Installed Drive Devices” on page 2-49.
009
(From steps 003 and 008)
DOES THE SYSTEM UNIT FAIL TO SHUT OFF WHEN THE ON/OFF
SWITCH IS PRESSED?
Yes No
010
Go to Step 006 on page 2-37.
011
– You might have a failing on/off switch assembly.
– Disconnect the on/off switch cable assembly connector from the client
card and take an ohm reading.
DO YOU HAVE AN OHM READING WHEN THE SWITCH IS PRESSED
AND AN OPEN READING WHEN THE SWITCH IS RELEASED?
Yes No
012
– Replace the on/off switch assembly.
013
– Replace the system board.
Check Procedures
2-39
Summary of Contents for Aptiva 2162 Series
Page 1: ...Hardware Maintenance Service for Service Level A Machine Type 2162 and IBM Monitors 2162...
Page 2: ......
Page 3: ...Hardware Maintenance Service for Service Level A Machine Type 2162 and IBM Monitors 2162...
Page 8: ...Appendix B Model Monitor Configurations and FRU Part Numbers B 1 Index X 1 vi...
Page 24: ...xxii...
Page 26: ...xxiv...
Page 126: ...2 72...
Page 144: ...3 18...
Page 188: ...6 2...
Page 192: ...Assembly 2 Machine Type 2162 System Unit Interior SL A 1 2 3 4 5 6 7 8 9 10 11 12 13 7 4...
Page 195: ...Assembly 3 Diskette and Hard Disk Drives 1 4 4 2 Parts Catalog 7 7...
Page 204: ...7 16...
Page 216: ...B 8...
Page 221: ......