v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
00151500
Excessive Single Bit Errors Detected
DIMM=
xx
1.
Reseat DIMM
xx
and the expansion unit if one is
installed.
v
DIMMs - See “Removing a memory module”
on page 44 and “Installing a memory module”
on page 46.
v
Optional expansion unit - See “Removing an
optional expansion unit” on page 37 and
“Installing an optional expansion unit” on
page 38.
2.
Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a.
DIMM
xx
- See “Removing a memory
module” on page 44 and “Installing a
memory module” on page 46.
b.
Optional expansion unit (if one is installed) -
See “Removing an optional expansion unit”
on page 37 and “Installing an optional
expansion unit” on page 38.
c.
(Trained service technician only) System-board
assembly - See “Removing the system-board
assembly” on page 65 and “Installing the
system-board assembly” on page 66.
00151700
Started Hot Spare memory Copy. Failed
row/rows=
xx
and
yy
copied to spare
row/rows=
aa
and
bb
1.
Reseat a DIMM - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46. See error code 00151500 to
determine which DIMM to reseat.
2.
Replace a DIMM - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46. See error code 00151500 to
determine which DIMM to replace.
00151710
Completed Hot Spare memory Copy. Failed
row/rows=
xx
and
yy
copied to spare
row/rows=
aa
and
bb
1.
Reseat a DIMM - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46. See error code 00151500 to
determine which DIMM to reseat.
2.
Replace a DIMM - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46. See error code 00151500 to
determine which DIMM to replace.
110
BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
Summary of Contents for BladeCenter HS12 Type 1916
Page 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...