v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
166-911-xxx
Failed the BMC self test due to a failure in the
BSE-3 PCI-X A slot.
1.
Turn off the blade server. See “Turning off the
blade server” on page 10.
2.
Open the blade server release levers and pull
the blade server away from the blade server
bay, but do not remove it. See “Removing the
blade server from the BladeCenter unit” on
page 33.
3.
Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 34 and “Turning on
the blade server” on page 9.
4.
Rerun the test. See “Diagnostic tools overview”
on page 67.
5.
Make sure that the DSA Diagnostic code is
up-to-date, upgrade if necessary; then, rerun
the test. The latest code can be found on the
IBM support Web site at http://
www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
6.
Make sure that the BMC firmware level is
up-to-date, upgrade if necessary; then, rerun
the test. The installed firmware level can be
found in the DSA Diagnostic Event Log within
the Firmware/VPD section for this component.
The latest level firmware for this component
can be found on the IBM support Web site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-4JTS2T.
7.
Turn off the blade server, open the blade server
release levers and pull the blade server away
from the blade server bay, but do not remove it
from the bay. See “Removing the blade server
from the BladeCenter unit” on page 33.
8.
Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 34 and “Turning on
the blade server” on page 9.
9.
Rerun the test. See “Diagnostic tools overview”
on page 67.
10.
If the failure remains, see Chapter 5,
“Removing and replacing blade server
components,” on page 31.
146
BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
Summary of Contents for BladeCenter HS12 Type 1916
Page 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...