v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
0058004
Mirror failover complete.
1.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
2.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
3.
Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 63).
4.
Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 64).
5.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95).
0058006
Spare copy failover complete.
1.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
2.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
3.
Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 63).
4.
Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 64).
5.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95).
0058007
Unsupported DIMM population
1.
Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
2.
Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
152
BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide
Summary of Contents for BladeCenter HS22V 7871
Page 1: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 20: ...4 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 34: ...18 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 64: ...48 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 112: ...96 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 240: ...224 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 244: ...228 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 252: ...236 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Part Number 00Y8038 Printed in USA 1P P N 00Y8038...