Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-786
304 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-789
2CD 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-78A
2CE 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-78B
2CC 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
187.
651-809
Power fault warning due to unspecified cause.
Go to “Performing the checkout procedure” on page 187.
651-810
2E2
Over-voltage condition was detected.
Do the following procedure before replacing any FRUs:
1.
Shut the system down.
2.
Visually inspect the power cables and reseat the connectors.
3.
Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select
sysplanar0
.
651-811
2E2
Under voltage condition was detected
Do the following procedure before replacing any FRUs:
1.
Shut the system down.
2.
Visually inspect the power cables and reseat the connectors.
3.
Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select sysplanar0.
651-813
System shutdown due to loss of ac power to the site. System resumed normal
operation, no action required.
651-818
Power fault due to manual activation of power-off request. Resume normal
operation.
651-820
2E1
An over-temperature condition was detected.
1.
Make sure that:
v
The room ambient temperature is within the system operating environment
v
There is unrestricted air flow around the system
2.
Replace the system-board and chassis assembly.
651-821
2E1
System shutdown due to an over maximum temperature condition being reached.
1.
Make sure that:
v
The room ambient temperature is within the system operating environment
v
There is unrestricted air flow around the system
2.
Replace the system-board and chassis assembly.
651-822
2E1
System shutdown due to over temperature condition and fan failure. Use the
physical FRU location(s) as the probable cause(s). Use the physical location codes to
replace the FRUs that are identified on the diagnostics problem report screen.
651-831
2E2
Sensor detected a voltage outside of the normal range. Go to “Performing the
checkout procedure” on page 187.
651-832
G2E1
Sensor detected an abnormally high internal temperature. Make sure that:
1.
The room ambient temperature is within the system operating environment.
2.
There is unrestricted air flow around the system.
3.
There are no fan failures.
148
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...