Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
652-731
2C8
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 187.
652-732
2C8
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-733
2C8 292
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 187.
652-734
2C8 292
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-735
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-736
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-770
2C8 292
A non-critical error has been detected: intermediate system bus address parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-771
2C8 292
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-772
2D2 292
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-773
227
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
187.
652-88x
The CEC or SPCN reported a non-critical error.
1.
Schedule deferred maintenance.
2.
Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3.
If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
652-89x
The CEC or SPCN reported a non-critical error.
1.
Schedule deferred maintenance.
2.
Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3.
If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
814-112
814
The NVRAM test failed. Go to “Performing the checkout procedure” on page 187.
814-113
221
The VPD test failed. Go to “Performing the checkout procedure” on page 187.
814-114
814
I/O Card NVRAM test failed. Go to “Performing the checkout procedure” on page
187.
150
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...