Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A0D-09x
Service Processor error accessing Vital
Product Data EEPROM.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-18x
Service Processor detected NVRAM
error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-19x
Service Processor error accessing Real
Time Clock/Time-of-Day Clock.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-21x
Service Processor detect error with
Time-of-Day Clock backup battery.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-23x
Loss of heart beat from Service
Processor.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-24x
Service Processor detected a
surveillance time-out.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-31x
Error detected while handling an
attention/interrupt from the system
hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A0D-35x
Mainstore or Cache IPL Diagnostic
Error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
Chapter 2. Diagnostics
167
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...