Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
6012
During the startup of a partition, the
partition LID failed to completely
load into the partition main storage
area.
Go to “Isolating firmware problems” on page 222.
6015
A problem occurred during the
startup of a partition. The load
source media is corrupted or not
valid.
Replace the load source media.
6025
A problem occurred during the
startup of a partition. This is a
problem with the load source media
being corrupt or not valid.
Replace the load source media.
6027
During the startup of a partition, a
failure occurred when allocating
memory for an internal object used
for firmware module load
operations.
1.
Make sure that enough main storage was allocated to
the partition.
2.
Retry the operation.
6110
A problem occurred during the
startup of a partition. There was an
error on the load source device. The
startup will attempt to continue.
Look for other errors and resolve them.
690A
During the startup of a partition, an
error occurred while copying open
firmware into the partition load area.
Go to “Isolating firmware problems” on page 222.
7200
Informational system log entry only.
No corrective action is required.
8080
Informational system log entry only.
No corrective action is required.
8081
During the startup of a partition, an
internal firmware time-out occurred;
the partition might continue to start
up but it can experience problems
while running.
Check for server firmware updates; then, install the
updates if available.
8105
During the startup of a partition,
there was a failure loading the VPD
areas of the partition; the load source
media has been corrupted or is
unsupported on this server.
Check for server firmware updates; then, install the
updates if available.
8106
A problem occurred during the
startup of a partition. The startup
will not continue.
Replace the load source media.
8107
During the startup of a partition,
there was a problem getting a
segment of main storage in the blade
server main storage.
Check for server firmware updates; then, install the
updates if available.
36
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...