Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
8109
During the startup of a partition, a
failure occurred. The startup will not
continue.
1.
Make sure that there is enough memory to start up
the partition.
2.
Check for server firmware updates; then, install the
updates if available.
8111
A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
8112
During the startup of a partition, a
failure occurred; the startup will not
continue.
Check for server firmware updates; then, install the
updates if available.
8113
During the startup of a partition, an
error occurred while mapping
memory for the partition startup.
Check for server firmware updates; then, install the
updates if available.
8114
During the startup of a partition,
there was a failure verifying the
VPD for the partition resources
during startup.
Check for server firmware updates; then, install the
updates if available.
8115
During the startup of a partition,
there was a low level
partition-to-partition communication
failure.
Check for server firmware updates; then, install the
updates if available.
8117
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Check for server firmware updates; then, install the
updates if available.
8121
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8123
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8125
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8127
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8129
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
813A
There was a problem establishing a
console.
Go to “Isolating firmware problems” on page 222.
8140
Informational system log entry only.
No corrective action is required.
8141
Informational system log entry only.
No corrective action is required.
8142
Informational system log entry only.
No corrective action is required.
8143
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
37
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...