Table 13. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
1730
The VPD for the system is not what was
expected at startup.
Replace the management card, as described in
“Removing the management card” on page 253
and “Installing the management card” on page
254.
1731
The VPD on a memory DIMM is not
correct and the memory on the DIMM
cannot be used, resulting in reduced
memory.
Replace the MEMDIMM symbolic CRU, as
described in “Service processor problems” on
page 205.
1732
The VPD on a processor card is not
correct and the processor card cannot be
used, resulting in reduced processing
power.
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
274.
1733
System firmware failure. The startup
will not continue.
Look for and correct B1xxxxxx errors. If there
are no serviceable B1xxxxxx errors, or if
correcting the errors does not correct the
problem, contact IBM support to reset the
server firmware settings.
Attention:
Resetting the server firmware
settings results in the loss of all of the partition
data that is stored on the service processor.
Before continuing with this operation,
manually record all settings that you intend to
preserve.
The service processor reboots after IBM
Support resets the server firmware settings.
If the problem persists, replace the
system-board and chassis assembly, as
described in “Replacing the Tier 2
system-board and chassis assembly” on page
274.
173A
A VPD collection overflow occurred.
1.
Look for and resolve other errors.
2.
If there are no other errors:
a.
Update the firmware to the current
level, as described in “Updating the
firmware” on page 277.
b.
You might also have to update the
management module firmware to a
compatible level.
173B
A system firmware failure occurred
during VPD collection.
Look for and correct other B1xxxxxx errors.
4091
Informational system log entry only.
No corrective action is required.
4400
There is a platform dump to collect
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 222.
42
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...