Table 13. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
6909
System bus error
1.
Replace the system-board and chassis
assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly”
on page 274.
2.
Go to “Isolating firmware problems” on
page 222.
6944
Informational system log entry only.
No corrective action is required.
6950
A platform dump has occurred.
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 222.
6951
An error occurred because a partition
needed more NVRAM than was
available.
Use the Integrated Virtualization Manager
(IVM) to delete one or more partitions.
6952
Informational system log entry only.
No corrective action is required.
6953
PHYP NVRAM is unavailable after a
service processor reset and reload.
Go to “Isolating firmware problems” on page
222.
6954
Informational system log entry only.
No corrective action is required.
6955
Informational system log entry only.
No corrective action is required.
6956
An NVRAM failure was detected.
Go to “Isolating firmware problems” on page
222.
6965
Informational system log entry only.
No corrective action is required.
6970
PCI host bridge failure
1.
Replace the system-board and chassis
assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly”
on page 274.
2.
If the problem persists, use the “PCI
expansion card (PIOCARD) problem
isolation procedure” on page 200 to
determine the failing component.
6971
PCI bus failure
1.
Use the “PCI expansion card (PIOCARD)
problem isolation procedure” on page 200
to determine the failing component.
2.
If the problem persists, replace the
system-board and chassis assembly, as
described in “Replacing the Tier 2
system-board and chassis assembly” on
page 274.
6972
System bus error
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
274.
Chapter 2. Diagnostics
45
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...