Table 22. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2607-706
2607
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
2624-xxx
2624
Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-101
2624
Configuration failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-102
2624
Queue pair create failure - system-board and chassis assembly. Go to “Performing
the checkout procedure” on page 187.
2624-103
2624
Loop back test failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-201
cable
network
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
2624-301
cable
network
2624
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
5.
Go to “Performing the checkout procedure” on page 187.
2624-701
2624
Error Log Analysis indicates that this adapter has failed due to an internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-702
2624
Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor - system-board and
chassis assembly. Go to “Performing the checkout procedure” on page 187.
2624-703
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-704
2624
Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-705
2624
Error Log Analysis indicates that this adapter has failed due to a internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-706
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2631-xxx
2631
Generic reference for IDE controller - system-board and chassis assembly. Go to
“Performing the checkout procedure” on page 187.
158
JS22 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......
Page 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...