Table 25. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
Description and action
ssss-108
ssss
The bus test failed.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-110
ssss
The media format is corrupted.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-112
ssss
The diagnostic test failed.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-114
ssss
An unrecoverable hardware error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-116
ssss
A protocol error.
1.
Make sure that the device, adapter and diagnostic firmware, and the application
software levels are compatible.
2.
If you do not find a problem, call your operating-system support person.
ssss-117
ssss
A write-protect error occurred.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-118
ssss 252B
A SCSI command time-out occurred.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-120
ssss
A SCSI busy or command error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
Chapter 2. Diagnostics
181
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......
Page 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...