B700 xxxx Error Codes
Description
Action
0103
System firmware detected a failure
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
0104
System firmware failure. Machine check,
undefined error occurred.
1.
Check for server firmware updates.
2.
Update the firmware.
0105
System firmware detected an error.
More than one request to terminate the
system was issued.
Go to “Isolating firmware problems” on page
222.
0106
System firmware failure.
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
0107
System firmware failure. The system
detected an unrecoverable machine
check condition.
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
0200
System firmware has experienced a low
storage condition
No immediate action is necessary.
Continue running the system normally. At the
earliest convenient time or service window,
work with IBM Support to collect a platform
dump and restart the system; then, go to
“Isolating firmware problems” on page 222.
0201
System firmware detected an error.
No immediate action is necessary.
Continue running the system normally. At the
earliest convenient time or service window,
work with IBM Support to collect a platform
dump and restart the system; then, go to
“Isolating firmware problems” on page 222.
0302
System firmware failure
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 222.
0441
Service processor failure. The platform
encountered an error early in the
startup or termination process.
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
0443
Service processor failure.
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
40
JS22 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......
Page 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...