Table 12. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
6994
Service processor failure.
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
6995
Informational system log entry only.
No corrective action is required.
69C2
Informational system log entry only.
No corrective action is required.
69C3
Informational system log entry only.
No corrective action is required.
69D9
Host Ethernet Adapter (HEA) failure.
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
69DA
Informational system log entry only.
No corrective action is required.
69DB
System firmware failure.
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 222.
BAD1
The platform firmware detected an
error.
Go to “Isolating firmware problems” on page
222.
F103
System firmware failure
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
F104
Operating system error. System
firmware terminated a partition.
Check the management-module event log for
partition firmware error codes (especially
BA00F104); then, take the appropriate actions
for those error codes.
F105
System firmware detected an internal
error
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
F106
System firmware detected an error
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
F10A
System firmware detected an error
Look for and correct B1xxxxxx errors.
F10B
A processor resource has been disabled
due to hardware problems
Replace the system-board and chassis
assembly, as described in “Replacing the Tier 2
system-board and chassis assembly” on page
270.
F120
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
47
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......