Table 24. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A24-xxx
Spurious interrupts have exceeded
threshold.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
Replace part numbers reported by the
diagnostic program.
3.
If no entry is found, replace the system-board
and chassis assembly.
ssss-102 through ssss-640 SRNs for SCSI devices
These service request numbers (SRNs) identify a SCSI device problem.
Use Table 25 to identify an SRN when you suspect a SCSI device problem. Replace
the parts in the order that the failing function codes (FFCs) are listed.
Notes:
1.
Some SRNs might have 4 digits rather than 3 digits after the dash (–).
2.
The
ssss
before the dash (–) represents the 3 digit or 4 digit SCSI SRN.
Table 25. ssss-102 through ssss-640 SRNs
SRN
FFC
Description and action
ssss-102
ssss
An unrecoverable media error occurred.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-104
ssss
The motor failed to restart.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-105
ssss
The drive did not become ready.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
ssss-106
ssss
The electronics card test failed.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 270.
180
JS22 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......
Page 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...