Table 11. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
F003
During the startup of a partition, the
partition processor(s) did not start
the firmware within the time-out
window.
Collect the partition dump information; then, go to
“Isolating firmware problems” on page 222.
F004
Informational system log entry only.
No corrective action is required.
F005
Informational system log entry only.
No corrective action is required.
F006
During the startup of a partition, the
code load operation for the partition
startup timed out.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 222.
F007
During a shutdown of the partition,
a time-out occurred while trying to
stop a partition.
Check for server firmware updates; then, install the
updates if available.
F008
Informational system log entry only.
No corrective action is required.
F009
Informational system log entry only.
No corrective action is required.
F00A
Informational system log entry only.
No corrective action is required.
F00B
Informational system log entry only.
No corrective action is required.
F00C
Informational system log entry only.
No corrective action is required.
F00D
Informational system log entry only.
No corrective action is required.
B700xxxx Licensed internal code SRCs
A B700xxxx system reference code (SRC) is an error code that is related to licensed
internal code.
Table 12 describes the error codes that may be displayed if POST detects a
problem. Suggested actions to correct the problem are also described.
Note:
For problems persisting after completing the suggested actions, see
“Checkout procedure” on page 186 and “Solving undetermined problems” on page
231.
Table 12. B700xxxx Licensed internal code SRCs
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
0102
System firmware detected an error. A
machine check occurred during startup.
1.
Collect the event log information.
2.
Go to “Isolating firmware problems” on
page 222.
Chapter 2. Diagnostics
39
Summary of Contents for BladeCenter JS22
Page 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Page 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Page 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Page 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Page 313: ......