Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, type 7891,” on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA310020
An invalid SRC history was obtained.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA310030
Writing the MAC address to the VPD
failed.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA330000
Memory allocation error.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA330001
Memory allocation error.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA330002
Memory allocation error.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA330003
Memory allocation error.
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.