Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
252B-719
252B
Device bus termination power lost or not detected.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
252B-720
252B
Adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
252B-721
252B
Temporary adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
252B-722
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
252B-723
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded by
the system, see “POST progress codes (checkpoints)” on page 97.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
254E-201
254E 221
Adapter configuration error. Go to “Performing the checkout procedure” on page 177.
254E-601
254
Error log analysis indicates adapter failure. Go to “Performing the checkout procedure”
on page 177.
254E-602
254
Error log analysis indicates an error attention condition. Go to “Performing the
checkout procedure” on page 177.
254E-603
254
Error log analysis indicates that the microcode could not be loaded on the adapter. Go
to “Performing the checkout procedure” on page 177.
254E-604
254
Error log analysis indicates a permanent adapter failure. Go to “Performing the
checkout procedure” on page 177.
254E-605
254
Error log analysis indicates permanent adapter failure is reported on the other port of
this adapter. Go to “Performing the checkout procedure” on page 177.
254E-606
254
Error log analysis indicates adapter failure. Go to “Performing the checkout procedure”
on page 177.
254E-701
254E 221
Error log analysis indicates permanent adapter failure. Go to “Performing the checkout
procedure” on page 177.
254E-702
254E 221
Error log analysis indicates permanent adapter failure is reported on the other port of
this adapter. Go to “Performing the checkout procedure” on page 177.
2567-xxx
2567
USB integrated system-board and chassis assembly. Go to “Performing the checkout
procedure” on page 177.
148