Table 11. 6xxxyyyy SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, type 7891,” on page 225 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Error Codes
Description
Action
632CC301
Media or device error
occurred.
Refer to the hosting partition for problem analysis.
632CC302
Media or device error
occurred.
Refer to the hosting partition for problem analysis.
632CC303
Media has an unknown
format.
No corrective action is required.
632CC333
Incompatible media.
1.
Verify that the disk has a supported format.
2.
If the format is supported, clean the disk and attempt the
failing operation again.
3.
If the operation fails again with the same system reference code,
ask your media source for a replacement disk.
632CC400
Physical link error detected by
device.
Refer to the hosting partition for problem analysis.
632CC402
An internal program error
occurred.
Install any available operating system updates.
632CCFF2
Informational system log entry
only.
No corrective action is required.
632CCFF4
Internal device error occurred.
Refer to the hosting partition for problem analysis.
632CCFF6
Informational system log entry
only.
No corrective action is required.
632CCFF7
Informational system log entry
only.
No corrective action is required.
632CCFFE
Informational system log entry
only.
No corrective action is required.
632CFF3D
Informational system log entry
only.
No corrective action is required.
632CFF6D
Informational system log entry
only.
No corrective action is required.
Chapter 2. Diagnostics