Note:
The power management policy that you have implemented for the
BladeCenter S system determines the result of a power module failure.
Power modules also provide cooling fans for the storage modules. Therefore,
if you are using storage module 1, you must install power modules 1 and 2. If
you are using storage module 2, you must install power modules 3 and 4.
–
Fan modules
. In normal operation, fan modules share the cooling in the
BladeCenter S system. If one fan module fails, the other three fan modules
handle the entire load. You can replace a fan module without shutting down
the BladeCenter S system.
–
BladeCenter S system midplane
. The midplane has the following
characteristics:
- Redundant high-speed serialize/deserialize (SERDES) interconnects
between blade servers and switches
- I2C communication between the advanced management module and all
modules (except blade servers)
- RS-485 (EIA 485) communication between the advanced management
module and blade servers
- Analog video connectors from the blade servers to the advanced
management module
- USB connections between the blade servers and the advanced management
module
–
Redundant storage access
. Installing a pair of SAS connectivity modules or
SAS RAID controller modules in I/O module bays 3 and 4 provides support
for redundant access to the storage modules in the BladeCenter S chassis (if
both storage modules are installed).
v
Systems management
The advanced management module is used to communicate with the service
processor in each blade server to provide system monitoring, event recording,
and alerts. You can manage the BladeCenter S chassis, its devices, and the blade
servers remotely.
Related documentation
In addition to this document, the following related documentation is provided in
Portable Document Format (PDF) on the IBM
BladeCenter Documentation
CD that
comes with your BladeCenter S chassis.
Note:
The latest and most up-to-date product information for the BladeCenter S
Types 7779 and 8886 can be found at the IBM Systems Information Center, which
is at http://publib.boulder.ibm.com/infocenter/systems/index.jsp. To access the
BladeCenter S system documentation from this site, click
Systems hardware
>
BladeCenter information
>
Chassis
>
BladeCenter S (8886)
.
In addition to the product documentation, online education is also available at this
location.
v
BladeCenter S Types 7779 and 8886 Planning Guide
This document contains information to plan for the physical installation and
configuration of the BladeCenter S Types 7779 and 8886.
v
BladeCenter S Types 7779 and 8886 Installation and User's Guide
This document contains information about setting up and configuring
yourBladeCenter S Types 7779 and 8886 and its components.
v
Serial over LAN Setup Guide
2
BladeCenter S Type 7779/8886: Problem Determination and Service Guide
Summary of Contents for BladeCenter S
Page 1: ...IBM BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...IBM BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 128: ...114 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 132: ...118 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 144: ...130 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 145: ......
Page 146: ... Part Number 94Y7083 Printed in USA 1P P N 94Y7083 ...