v
This is the default for Telnet sessions.
v
The terminal application PuTTY has a configuration setting for the Return
key. From the Configuration menu, click
Connection
→
Telnet
.
2.
The service processor on older blade servers might block SOL output to a blade
server running Linux. If this occurs, type
Ctrl-q
in the Serial over LAN session
to clear the keystroke buffer.
3.
Verify that the operating system running on the blade server supports Serial
over LAN. For more information see the
IBM BladeCenter Serial over LAN Setup
Guide
.
4.
Make sure that the operating system running on the blade server has been set
up correctly for Serial over LAN console access. For more information see the
IBM BladeCenter Serial over LAN Setup Guide
.
Characters received or typed are incorrect
Use this procedure when you are having trouble typing or receiving correct
characters in a Serial over LAN session.
Problem
Within a Serial over LAN session, the characters that you type appear differently
on the terminal.
Investigation
Perform these steps to resolve the problem:
1.
Verify that the serial port settings in your terminal emulation program match
the settings in the blade server BIOS configuration. In addition, verify that
hardware flow control is enabled.
2.
Try a different terminal emulation program, such as Telnet, PuTTY, or
Hyperterm.
3.
Make sure the Ethernet switch in I/O module bay 1 is powered on.
4.
Check the external link statistics for the Ethernet switch in I/O module bay 1.
Look for high packet loss and/or high packet error rates.
5.
Attempt to set up a Serial over LAN session to another blade server in the
BladeCenter S chassis. If the problem persists for multiple blade servers,
suspect the advanced management module.
6.
Restart the blade server. From the advanced management module Web
interface, click
Blade Tasks
>
Power/Restart
. Click the box next to the blade
server, and then scroll down and select
Restart Blade System Mgmt Processor
.
a.
Make sure the blade server is powered up.
b.
Check the status of Serial over LAN.
c.
If it is ready, attempt to open an Serial over LAN console.
7.
Update the Baseboard Management Controller (BMC) and the Ethernet driver
for the blade server.
8.
If the blade server supports local KVM, attempt to access the blade server
using the KVM connection on the advanced management module and type
some characters. If the problem persists, suspect the advanced management
module.
Troubleshooting storage module problems
Use this information to solve problems with the storage module and hard disk
drives.
70
BladeCenter S Type 7779/8886: Problem Determination and Service Guide
Summary of Contents for BladeCenter S
Page 1: ...IBM BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...IBM BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 128: ...114 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 132: ...118 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 144: ...130 BladeCenter S Type 7779 8886 Problem Determination and Service Guide ...
Page 145: ......
Page 146: ... Part Number 94Y7083 Printed in USA 1P P N 94Y7083 ...