Management-module error messages
Note:
See Chapter 7, “Parts listing,
BladeCenter T Type 8267
,” on page 101 to determine which components should
be replaced by a field service technician.
Message
Action
Application posted alert to ASM
The alert button on the Web interface was tested. Information only.
Take action as required.
System log 75% full
Information only. Take action as required.
System log full
Information only. Take action as required.
Management module network
initialization complete
Information only. Take action as required.
Remote login successful. Login ID
Information only. Take action as required.
ASM reset was caused by restoring
default values
The management-module assembly was reset after restoring the
default settings. Information only. Take action as required.
ASM reset was initiated by the user
Information only. Take action as required.
Pushbutton reset activated: Ethernet
configuration reset to default values and
MM ASM reset due to watchdog timeout
1.
Reseat the management module.
2.
Reflash the management-module firmware.
3.
Replace the management module.
ASM reset due to XXXXX, instruction
fault: XXXXXXXX YYYYYYYY ZZZZZZ
1.
Reseat the management module.
2.
Reflash the management-module firmware.
3.
Replace the management module.
ASM reset reason unknown
Information only.
Possible ASM reset occurred reason
unknown
Information only.
Remote access attempt failed. Invalid
userid or password received. User is XXX
from CMD mode client at
IP@=XXX.XXX.XXX.XXX
Failed attempt to log into the management module.
Remote access attempt failed. Invalid
userid or password received. User is XXX
from WEB browser
IP@=XXX.XXX.XXX.XXX
Failed attempt to log into the management module.
DHCP [X] failure, no IP @ assigned (retry
X), rc=X
Failed to get IP address by DHCP server. Check the DHCP server
connection and settings.
LAN: Command mode tamper triggered.
Possible break in attempt.
Unsuccessful attempt to access the management module in command
mode. Information only. Take action as required.
LAN: WEB server tamper delay triggered.
Possible break in attempt.
Unsuccessful attempt to access the management module in command
mode. Information only. Take action as required.
System log cleared.
Information only. Take action as required.
Chapter 6. Symptom-to-FRU index
97
Summary of Contents for BladeCenter T
Page 1: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 16: ...xiv BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 20: ...xviii BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 52: ...32 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 102: ...82 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 126: ...106 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 138: ...118 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 139: ......
Page 140: ... Part Number 94Y7061 Printed in USA 1P P N 94Y7061 ...