Configuring the external Ethernet port
Under
MM Control
, click
Network Interfaces ” External Network Interface (eth0)
.
This is the interface for the remote management and console port.
v
Set
Interface
to
Enabled
to use the Ethernet connection.
v
If you plan to use redundant management modules and want both to use the
same IP address, disable DHCP and configure and use a static IP address (the IP
configuration information will be transferred to the redundant management
module automatically when needed). Otherwise, configure the DHCP setting as
you prefer. You must configure the static IP address only if DHCP is disabled.
–
IP address
- The IP address for the management module. The IP address
must contain four integers from 0 through 255, separated by periods, with no
spaces or consecutive periods. The default setting is 192.168.70.125.
–
Subnet mask
- The subnet mask must contain four integers from 0 to 255,
separated by periods, with no spaces. The default setting is 255.255.255.0
–
Gateway address
- The IP address for your network gateway router. The
gateway address must contain four integers from 0 through 255, separated by
periods, with no spaces.
Configuring the internal Ethernet port
Under
MM Control
, click
Network Interfaces ” Internal Network Interface (eth1)
.
This interface communicates with the network-interface I/O modules, such as the
Ethernet switch module or the Fibre Channel switch module.
v
Specify the IP address to use for this interface. The IP addresses for the internal
Ethernet port (eth1) and external Ethernet port (eth0) must be on the same
subnet.
v
(Optional) Configure the locally-administered MAC address for this interface;
the other fields (data rate, duplex mode, maximum transmission unit (MTU),
and burned-in MAC address) are read-only.
Chapter 2. Configuring the BladeCenter T unit
25
Summary of Contents for BladeCenter T
Page 1: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 16: ...xiv BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 20: ...xviii BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 52: ...32 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 102: ...82 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 126: ...106 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 138: ...118 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 139: ......
Page 140: ... Part Number 94Y7061 Printed in USA 1P P N 94Y7061 ...