v
Yes :
Click
Recovery Guru
in the Subsystem Management window toolbar and complete the
recovery procedure. If a problem is still indicated, contact your IBM technical-support
representative.
v
No:
Go to step 21.
21.
Create, save, and print a new storage subsystem profile.
Replacing a battery
About this task
The controller in the DCS3700 storage system contains a rechargeable battery backup unit that provides
power to back up the cache memory onto flash memory in the event of a power failure. Each battery unit
contains a sealed, rechargeable SMART lithium ion battery. The cache battery is the only replaceable
battery in the storage subsystem.
Use the following procedure if the Storage Manager software instructs you to replace the battery because
the current battery has failed. You can also use the Storage Manager software to check the status of the
battery. Because write-caching is disabled when the battery fails, replace the failed battery as soon as
possible to minimize any performance impact due to the disabling of the write-caching function.
Attention:
When you handle static-sensitive devices, take precautions to avoid damage from static
electricity. For details about handling static-sensitive devices, see the safety information in the prolog of
this document.
Attention:
To avoid overheating the storage enclosure and causing damage to its components, replace
failed parts within 10 minutes. The Recovery Guru in the Storage Manager software identifies failed
parts.
Do not remove the failed part from the storage enclosure until you:
v
Review the replacement procedure for the failed part in this guide.
v
Locate screw drivers or any other hand tools that you might need to replace the failed part.
v
Receive the replacement part and are ready to install it in the enclosure.
To replace a battery unit, complete the following steps:
Procedure
1.
Use the Storage Manager software to print a storage subsystem profile.
2.
Read the safety information found in the prolog of this document.
3.
Locate the controller that contains the failed battery unit .
4.
Remove the controller from the chassis.
Chapter 5. Replacing components
113
Summary of Contents for DCS3700
Page 1: ...IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 2: ......
Page 3: ...IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 8: ...vi IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 12: ...x IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 18: ...xvi IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 22: ...xx IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 62: ...40 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 75: ...Figure 34 Single Expansion Enclosures Chapter 3 Cabling the DCS3700 53...
Page 88: ...66 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 150: ...128 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 168: ...146 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 178: ...156 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 180: ...158 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 188: ...166 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 198: ...176 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 201: ......
Page 202: ...Part Number 90Y8588 Printed in USA 1P P N 90Y8588...