Chapter
7.
PDU
specifications
When
the
PDU
is
connected
to
a
dedicated
power
source,
it
conforms
to
UL60950,
CSA
C22.2-60950,
EN-60950,
and
IEC-60950
standards.
The
following
table
contains
the
product
specifications
for
the
PDUs.
The
PDUs
in
the
following
list
correspond
by
number
to
the
rated
voltages,
maximum
power
ratings,
and
power
cords
that
are
listed
in
the
table:
1.
DPI
32
amp/250
V
1-phase
Enterprise
C13
PDU
with
IEC
309
2P+N+Gnd
connector
2.
DPI
60
amp/208
V
1-phase
Enterprise
C13
PDU
with
IEC
309
2P+Gnd
connector
3.
DPI
63
amp/250
V
1-phase
Enterprise
C13
PDU
with
IEC
309
2P+N+Gnd
connector
4.
DPI
32
amp/250
V
3-phase
Enterprise
C13
PDU
with
IEC
309
3P+N+Gnd
connector
5.
DPI
30
amp/208
V
1-phase
Enterprise
C13
PDU
with
Nema
L6-30P
connector
6.
DPI
60
amp/208
V
3-phase
Enterprise
C13
PDU
with
IEC
309
3P+Gnd
connector
7.
DPI
60
amp/208
V
1-phase
Enterprise
C19
PDU
with
IEC
309
2P+Gnd
connector
8.
DPI
63
amp/250
V
1-phase
Enterprise
C19
PDU
with
IEC
309
2P+N+Gnd
connector
9.
DPI
32
amp/250
V
3-phase
Enterprise
C19
PDU
with
IEC
309
3P+N+Gnd
connector
10.
DPI
60
amp/208
V
3-phase
Enterprise
C19
PDU
with
IEC
309
3P+Gnd
connector
Height
43.9
mm
(1.73
in.)
Width
447
mm
(17.6
in.)
Depth
350
mm
(13.78
in.)
Additional
Clearance
25
mm
(0.98
in.)
for
circuit
breakers
3
mm
(0.12
in.)
for
outlets
Weight
(not
including
line
cord)
6.3
kg
(13.8
lb)
Weight
of
line
cord
(approximate,
varies
by
model
of
PDU)
5.4
kg
(11.8
lb)
Operating
temperature
at
0-914
m
(0-3000
ft)
(room
ambient)
10°-
35°C
(50°-
95°F)
Operating
temperature
at
914-2133
m
(3000-7000
ft)
(room
ambient)
10°-
32°C
(50°-
90°F)
Operating
humidity
8-80%
(noncondensing)
Localized
air
temperature
in
PDU
60°C
(140°F)
maximum
©
Copyright
IBM
Corp.
2006
43
Summary of Contents for DPI C13 PDU+
Page 1: ...DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 2: ......
Page 3: ...DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 20: ...8 DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 28: ...16 DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 48: ...36 DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 54: ...42 DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 58: ...46 DPI C13 PDU DPI C19 PDU and DPI C19 3 phase PDU Installation and Maintenance Guide...
Page 87: ......
Page 88: ...Part Number 40K9635 Printed in USA 1P P N 40K9635...