Table 2. Default settings for the diagnostic programs (continued)
General setup attributes
3151 /11/31/41
settings
3151 /51/61
settings
3161 /64
settings
Description
Word length (bits)
8
8
8
Selects 8 bits as a data word length
(byte).
Parity
No
No
No
Does not add a parity bit and is used
together with the word length attribute
to form the 8–bit data word (byte).
Stop bit
1
1
1
Places a bit after a data word (byte).
5.
Press a key on the ASCII terminal to allow the service processor to confirm the presence of the ASCII
terminal.
6.
When the login display appears for the ASMI, enter
admin
for the user ID and password.
7.
Change the default password when you are prompted.
8.
Press Enter until the server information appears. You have completed the setup for an ASCII terminal,
and have started the ASMI.
9.
Continue with “Completing the server setup without using an HMC” on page 26.
Cabling the server to the HMC
The Hardware Management Console (HMC) controls managed systems, including the management of
logical partitions, the creation of a virtual environment, and the use of capacity on demand. Using service
applications, the HMC can also communicate with managed systems to detect, consolidate, and forward
information to IBM service for analysis.
If you have not installed and configured your HMC, do so now. For instructions, see Installation and
configuration scenarios (http://www.ibm.com/support/knowledgecenter/POWER8/p8hai/
basichmcinstallationandconfigurationtaskflow.htm).
To manage POWER8 processor-based servers, the HMC must be at version 8 release 8.6.0, or later. To
view the HMC version and release, complete the following steps:
1.
In the navigation area, click Updates.
2.
In the work area, view and record the information that appears in the HMC Code Level section,
including the HMC version, release, Service Pack, build level, and base versions.
If you need to update your HMC version and release, see Obtaining and applying machine code updates
for the HMC with an Internet connection (http://www.ibm.com/support/knowledgecenter/POWER8/
p8hai/area3fixeshmc.htm).
To cable the server to the HMC, complete the following steps:
1.
If you want to directly attach your HMC to the managed system, connect Ethernet Connector 1 on
the HMC to the HMC1 (T4) port on the managed system.
20
Power Systems: Installing the IBM Power System E850C (8408-44E)
Summary of Contents for E850C
Page 1: ...Power Systems Installing the IBM Power System E850C 8408 44E GI11 9920 00 IBM...
Page 2: ......
Page 3: ...Power Systems Installing the IBM Power System E850C 8408 44E GI11 9920 00 IBM...
Page 6: ...iv Power Systems Installing the IBM Power System E850C 8408 44E...
Page 16: ...xiv Power Systems Installing the IBM Power System E850C 8408 44E...
Page 54: ...38 Power Systems Installing the IBM Power System E850C 8408 44E...
Page 67: ...Notices 51...
Page 68: ...IBM Part Number 29R2425 Printed in USA GI11 9920 00 1P P N 29R2425...