Chapter 4. Reliability, availability, and serviceability
105
IBM uses stringent design criteria to select server grade components that are extensively
tested and qualified to meet and exceed a minimum design life of seven years. By selecting
higher reliability grade components, the frequency of all failures is lowered, and wear-out is
not expected within the operating system life. Component failure rates can be further
improved by burning in select components or running the system before shipping it to the
client. This period of high stress removes the weaker components with higher failure rates,
that is, it cuts off the front end of the traditional failure rate bathtub curve (see Figure 4-1).
Figure 4-1 Failure rate bathtub curve
4.2.2 Placement of components
Packaging is designed to deliver both high performance and high reliability. For example, the
reliability of electronic components is directly related to their thermal environment. Large
decreases in component reliability are directly correlated to relatively small increases in
temperature. All POWER processor-based systems are packaged to ensure adequate
cooling. Critical system components, such as the POWER8 processor chips, are positioned
on the system board so that they receive clear air flow during operation. POWER8 systems
use a premium fan with an extended life to further reduce overall system failure rate and
provide adequate cooling for the critical system components.
The Power E850C has two cooling channels. The front fans provide cooling for the upper part
of the chassis, covering the memory cards, processors, and PCIe cards. These fans in this
assembly provide redundancy, and support concurrent maintenance. The lower system fans,
which are in the internal fan assembly, provide air movement for the lower part of the chassis,
including the disk backplane and RAID controllers. The fans in the internal fan assembly
provide redundancy, and also contain multiple integrated spares.
Failu
re Ra
te
(FIT
)
Power-on Hours
~
~
Early life
End-of-life
Average life
of a server
System
run-in
Wafer and chip test
In situ
burn-in
Summary of Contents for E850C
Page 2: ......
Page 36: ...22 IBM Power System E850C Technical Overview and Introduction...
Page 114: ...100 IBM Power System E850C Technical Overview and Introduction...
Page 154: ...140 IBM Power System E850C Technical Overview and Introduction...
Page 158: ...144 IBM Power System E850C Technical Overview and Introduction...
Page 159: ......
Page 160: ...ibm com redbooks Printed in U S A Back cover ISBN 0738455687 REDP 5412 00...