Chapter 2. Architecture and technical overview
75
Scenario 2: Basic redundant connection
This scenario assumes a single Virtual I/O Server with two PCIe SAS adapters #5901 and an
EXP24S set on mode 1. This configuration allows for up to 24 disks to be attached to the
server. Figure 2-28 shows the connection diagram and components of the solution.
Figure 2-28 Scenario 2: Basic redundant connection
The following are the required feature codes for this scenario:
One EXP24S drawer #5887 with indicator feature #9360 (mode 1 with dual #5901)
Two PCIe SAS adapter #5901
Two SAS YO cables 3 Gbps with proper length
The ports that are used on the SAS adapters must be the same for both adapters of the pair.
This scenario provides no SSD support.
EXP24S – Mode 1 with 2 x #5901 (config indicator #9360)
#5901
SAS YO Cable
Virtual
I/O
Server
#5901
#5901
Use
same
port on
the pair
GROUP 1
Summary of Contents for E850C