4. Remove the top cover. For more information, see “Removing the top cover” on page 44.
5. With two or more persons, push the expansion enclosure sideways onto an adjacent flatbed lift. Keep
the remaining foam block protectors attached to the enclosure.
6. Remove the support rail kit from the box in which it was shipped (
1
, as shown in Figure 12 on page
7. Separate the inner section of the support rails and attach them to each side of the expansion
enclosure. For more information, see steps “3” on page 45 through “5” on page 46 in “Installing or
replacing the support rails (IBM SSR task)” on page 45.
8. Attach the remaining sections of the support rails to the rack. For more information, see step “6” on
page 46 in “Installing or replacing the support rails (IBM SSR task)” on page 45.
9. Move the mechanical lift to the front of the rack. Align the inner section of the rails with the mid-
section of the rails that are extending from the rack.
10. On each side, push the inner section and middle section of the rails together until they click and will
no longer separate. For more information, see step “1” on page 56 in “Installing or replacing a
Model 092 expansion enclosure in a rack ” on page 55.
11. Remove the 4U fascia and the 1U fascia from the boxes in which they were shipped, as shown in
Figure 14. Packaging for fascia
1
4U fascia (front)
2
1U fascia (power supply units)
12. Attach the 4U fascia and the 1U fascia to the front of the enclosure. For more information, see
“Installing or replacing the fascia” on page 48.
13. Install the drives. For more information, see “Installing or replacing a drive” on page 49.
14. Replace the top cover. For more information, see “Installing or replacing the top cover” on page 54.
15. Lower the mechanical lift so that you can remove the remaining foam blocks away from the
expansion enclosure.
16. Slide the latch on the side of each rail and push the expansion enclosure securely into the rack. For
more information, see steps “4” on page 56 through “6” on page 56 in “Installing or replacing a
Model 092 expansion enclosure in a rack ” on page 55.
17. Remove the cable management arm assembly from its packaging (
2
18. Attach the cable management arm. For more information, see “Installing or replacing the cable
19. Connect the SAS cables. For more information, see “Removing and installing a SAS cable” on page
20. Connect the power cables.
Chapter 5. Installing Model 092 expansion enclosure 41
Summary of Contents for Elastic Storage System 5000 Series
Page 1: ...IBM Elastic Storage System 5000 Version 6 0 1 Model 092 Hardware Guide IBM SC28 3135 00...
Page 8: ...viii...
Page 10: ...24 Enclosure models and rack requirements 74 x...
Page 14: ...xiv IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 32: ...18 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 36: ...22 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 51: ...Figure 11 Cable connectivity from I O servers Chapter 4 Planning for hardware 37...
Page 86: ...72 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 90: ...76 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 98: ...84 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 100: ...86 IBM Elastic Storage System 5000 Model 092 Hardware Guide...
Page 101: ......
Page 102: ...IBM Product Number 5765 DME 5765 DAE SC28 3135 00...