Repeat the previous service procedure and swap out the mismatched PSU once the replacement PSU
is received.
Note: It is not recommended to use mismatched PSUs in a 5147-102 enclosure.
Miscellaneous equipment specification (MES) instructions
An IBM Elastic Storage System 5147-102 Storage Enclosure hardware change can be done by using the
MES instructions.
Upgrading an IBM Elastic Storage System 5147-102 Storage Enclosure from
a half-populated to a fully populated configuration
This non-concurrent MES procedure involves shifting down customer workload, adding 50 more HDDs
to an existing IBM Elastic Storage System 5147-102 Storage Enclosure to fill up all 102 drive slots with
HDDs, and returning the system to the customer for configuration of the new storage.
This procedure is only applicable to an IBM Elastic Storage System solution with a single half-populated
IBM Elastic Storage System 5147-102 Storage Enclosure.
MES upgrade steps
Refer to the following steps to upgrade an 5147-102 from a half-populated to a fully populated
configuration:
1. Customer task: Stop using the ESS 5147-102 enclosure.
2. Customer task: Unmount affected file systems that are mounted on the ESS 5147-102 enclosure and
shutdown GPFS.
mmshutdown -a
3. Identify the ESS 5147-102 storage enclosure to be upgraded.
a. Perform the following checks in the
essutils
menu and gather ESS 5147-102 serial number in
the SSR Checks for ESS 3500 nodes’ section:
i) Quick storage configuration check
ii) Check enclosure cabling and paths to disks
b. SSR Checks for ESS 3500 nodes > 1. Quick storage configuration check.
/opt/ibm/ess/tools/bin/essstoragequickcheck -N localhost
[INFO] Start of storage quick configuration check
[INFO] nodelist: localhost
[INFO] Checking node: localhost
[INFO] IO Server/Canister Type: ESS3500-5141-FN2, Serial: 78E400QB
[OK] Valid SAS Adapter Configuration. Number of Adapter(s) found: 1
[INFO] Slots of SAS Adapter found 41:00.0,
[OK] Valid Network Adapter Configuration. Number of Adapter(s) found: 2
[INFO] Slots of Network Adapter found 08:00.1, c1:00.0, c1:00.1, 08:00.0
[OK] NVMe Drv 15.36TB NVMe Tier-1 Flash found 24
[OK] Summary: total NVMe Drv found 24, expected NVMe Drv 24
[INFO] Found only Rotating disks inside enclosure.
[INFO] Enclosure 5147-102 found 1
[INFO] Disk ST10000NM0578 E found 52
[OK] Total disk found 52, expected 52
[INFO] Total ssd found 0, expected 0
[INFO] End of storage quick configuration check
[OK] essstoragequickcheck passed successfully
Press Enter to continue...
SSR Checks for ESS 3500 nodes > 2. Check enclosure cabling and paths to disks
/opt/ibm/ess/tools/bin/essfindmissingdisks -N localhost
[INFO] Start find missing disk paths
[INFO] nodelist: localhost
[INFO] May take long time to complete search of all drive paths
6 IBM Elastic Storage System 5147-10 Storage Enclosure: Service Guide
Summary of Contents for Elastic Storage System 5147-102
Page 1: ...IBM Elastic Storage System 5147 102 Storage Enclosure 6 1 5 Service Guide IBM SC31 5732 01...
Page 4: ...iv...
Page 6: ...vi...
Page 8: ...viii...
Page 54: ...44 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 56: ...46 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 60: ...50 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 68: ...58 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 70: ...60 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 71: ......
Page 72: ...IBM Product Number 5765 DME 5765 DAE SC31 5732 01...