--code 8+2P --block-size 4M --set-size
60% --da DA3 --nsd-usage dataOnly --storage-pool dataX
d. Create the new vdisk sets.
# mmvdisk vs create --vs all
e. Add the vdisk sets to the filesystem.
- add vdisk sets to the filesystem:
# mmvdisk fs add --fs <fsname> --vs <vsname1a, vsname1b>
- mmvdisk fs add --fs fs3500hyper --vs vs_fs3500hyper_1A,vs_fs3500hyper_1B
f. Recommendation: Restripe the filesystem as needed.
# mmrestripefs <fsname> -b
# mmrestripefs fs3500hyper -b
Adding up to four 5147-102 storage enclosures to an existing ESS 3500
capacity configuration
This MES procedure involves adding up to four IBM Elastic Storage System 5147-102 Storage Enclosures
to an existing capacity configuration using single and dual SAS adapter pairs.
Adding up to two 5147-102 storage enclosures using single SAS adapter pair
The capacity configuration consists of one 5141-FN2 server enclosure and one or more 5147-102 storage
enclosures with enterprise HDDs for data storage. This configuration requires four 3.8TB NVMe drives
installed in the 5141-FN2 server enclosure for Log Tip as part of the system management requirements.
The four 3.8TB NVMe drives for Log Tip are not available for user data storage and are located in drive slot
1, 2, 13, and 14.
Chapter 1. Servicing (customer task) 19
Summary of Contents for Elastic Storage System 5147-102
Page 1: ...IBM Elastic Storage System 5147 102 Storage Enclosure 6 1 5 Service Guide IBM SC31 5732 01...
Page 4: ...iv...
Page 6: ...vi...
Page 8: ...viii...
Page 54: ...44 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 56: ...46 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 60: ...50 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 68: ...58 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 70: ...60 IBM Elastic Storage System 5147 10 Storage Enclosure Service Guide...
Page 71: ......
Page 72: ...IBM Product Number 5765 DME 5765 DAE SC31 5732 01...