2
IBM® xSeries 150: Installation Guide
Features and specifications
Table 1 provides a summary of the features and specifications for your xSeries 150
server.
Table 1. Features and Specifications
Microprocessor:
•
1 or 2 Intel® Pentium® III
microprocessors with
MMX™ technology and
SIMD extensions, depending
on model
•
256 KB Level-2 cache (min.)
•
Supports up to two
microprocessors
Memory:
•
Standard: 256 MB or 1 GB,
depending on model
•
Maximum: 4 GB
•
Type: 133 MHz, ECC,
SDRAM, Registered DIMMs
•
Slots: 4 dual inline slots
Drives standard:
•
3 or 6 Hard Disk Drives,
depending on model
•
Diskette: 1.44 MB
•
CD-ROM: 40X IDE
Expansion bays:
•
Hot-swap: six slim high or
three half high
•
Non-hot-swap: Three 5.25-
inch (one used by CD-ROM
drive)
PCI expansion slots:
•
Three 33 MHz/64-bit
•
Two 33 MHz/32-bit
Power supplies:
250 watt (115-230 Vac)
•
Standard: One
•
Maximum: Three, only with
optional power backplane
that enables multiple power
supplies and hot-
swappability
Video:
•
S3 video controller (integrated on
system board)
•
Compatible with SVGA and VGA
•
8 MB SDRAM video memory
Size (Rack Model 5U)
•
Height: 220 mm (8.7 in.)
•
Depth: 630 mm (24.8 in.)
•
Width: 440 mm (17.3 in.)
•
Weight: approximately 35.38 Kg (78
lb.) when fully configured
Size (Tower Model)
•
Height: 440 mm (17.3 in.)
•
Depth: 660 mm (26.0 in.)
•
Width: 220 mm (8.7 in.)
•
Weight: approximately 36.74 Kg (81
lb.) when fully configured
Integrated functions:
•
Netfinity Advanced System
Management processor
•
ServeRAID 4L/4H PCI adapter
•
Dual channel Ultra3 SCSI controller
•
One integrated 10BASE-T/100BASE-
TX AMD Ethernet controller
•
1 or 3 Netfinity 10/100 Ethernet
Adapter 2s, depending on model
•
Two serial ports
•
One parallel port
•
Two Universal Serial Bus (USB) ports
•
Keyboard port
•
Mouse port
•
Video port
Acoustical noise emissions:
•
Sound power, idling: 6.0 bel
maximum
•
Sound power, operating: 6.0 bel
maximum
•
Sound pressure, operating: 45 dBa
maximum
Environment:
•
Air temperature:
— Server on: 10
to 35
C
(50.0
to 95.0
F).
Altitude: 0 to 914 m
(2998.7 ft.)
— Server on: 10
to 32
C
(50.0
to 89.6
F).
Altitude: 914 m (2998.7
ft.) to 2133 m (6998.0 ft.)
— Server off: 10
to 43
C
(50.0
to 109.4
F).
Maximum altitude: 2133
m (6998.0 ft.)
•
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
Thermal Units (BTU) per hour
•
Minimum configuration: 683
BTU (200 watts)
•
Maximum configuration:
2048 BTU (600 watts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
•
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
•
Input kilovolt-amperes
(kVA) approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA
Summary of Contents for eServer 150 xSeries
Page 1: ...IBM IBM xSeries 150 Installation Guide...
Page 2: ......
Page 3: ...IBM IBM xSeries 150 Installation Guide...
Page 10: ...viii IBM xSeries 150 Installation Guide...
Page 12: ...x IBM xSeries 150 Installation Guide...
Page 16: ...4 IBM xSeries 150 Installation Guide...
Page 24: ...12 IBM xSeries 150 Installation Guide...
Page 36: ...24 IBM xSeries 150 Installation Guide...
Page 40: ...28 IBM xSeries 150 Installation Guide...
Page 74: ...62 IBM xSeries 150 Installation Guide...
Page 75: ......